F-01 · Mechanical closet, second floor
Staining below the second-floor air handler
At the initial Month 3 report: Open
Sample finding
- Observed
- Dry discoloration on the platform beneath the air handler cabinet. No active dripping was seen on the visit day.
- Not determined
- The cause cannot be determined by looking. Staining alone does not show whether, when or why water was present.
- Recommendation
- Ask a qualified HVAC provider to evaluate the unit and its condensate drainage, after the owner approves.
1 · Observed. Dry discoloration on the platform below the cabinet.
2 · Not determined visually. Condensate drainage and the cause of the staining.
3 · Referred. Qualified HVAC evaluation after owner approval.
Owner decision & follow-through
- Day 1Observed and photographed; recommendation sent to the owner.
- Day 2Owner approved an HVAC evaluation; billed directly to the owner.
- Day 3Hypothetical HVAC provider completed the authorized scope; written service record SR-0003 received and filed.
- Month 4 visitFollow-up observation: no new staining at the marked area. Finding closed in the Property Record.
- Authorized scope
- Authorized Day 2: evaluate air handler 2 and its condensate drainage; clear the drain line if obstructed. Billed directly to the owner.
- Provider conclusion
- The hypothetical provider reported a partially obstructed primary condensate drain line, cleared and flushed it, and saw water flow to the drain termination during their visit. They described the staining as consistent with past overflow from that blockage.
“Primary condensate line partially obstructed at trap. Cleared and flushed line; observed flow to termination. Overflow safety switch tested and operating at time of service. Recommend routine condensate service.”
Evidence of closure. Closed at the Month 4 visit because three things were on file: the owner’s approval of a defined scope, the provider’s written record of what they found and did (SR-0003), and a follow-up observation with no new staining. The written record documents one service visit; it is not a guarantee, and closing a finding does not mean the condition cannot return.